Land in Bairro da Ana in Agualva with an approved project for a 4 bedroom villa in LSF Single-family Typology T4 Total Land Area: 175.38 m² Implantation area: 89.24 m² Building area: 178.48 m² Composed of 2 floors above ground level entirely for housing Ground floor with 89.24 m² Floor 1 with 89.24 m² The building will be equipped with a total of 2 private parking spaces for light vehicles inside the lot. Land Cover Index: 0.5088 Land Use Index: 1.0177 Covered Outdoor Area: 22.54 m² Waterproofed Area (maximum 122.77 m²): 116.06 m² Permeable Area (minimum 52.61 m²): 59.32 m² Soil Sealing Index (maximum 0.70): 0.6618 Soil Permeability Index (minimum 0.30): 0.3382 INFRASTRUCTURE Direct reinforced concrete foundations to be concreted on site, composed of general sunshading, with lintel beams on the edge of the sunshading and beams lined up under interior walls. Floor slab on the ground floor of the house in direct contact with the ground. About Sunbathing, embedded in the filling layer and regularisation in lightweight concrete, the appropriate infrastructures will be integrated. All Elements that make up the foundations, in direct contact with the ground, will be properly waterproofed and insulated. Will run a peripheral drainage system for correct rainwater drainage, consisting of a coated nodular drainage plastic membrane per geotextile filter layer Drainage pipe wrapped in filter geotextile and gravel. SUPERSTRUCTURE Lightened metal, in cold-formed, hot-dip galvanised steel profiles, with zinc plating of at least class S280gd, galvanised to hot - Z275, with 275gr/m2 of zinc plating, in the construction system called 'Light Steel Framing'. EXTERIOR Walls (Lsf) - Current Solution Single wall with thermal insulation from the outside, consisting from the inside to the outside of: - Paint (dry zone) or cement glue + ceramic coating (wet area) - Normal plasterboard (dry zone) or water-repellent (wet zone) plasterboard - 2x 1.25 cm - Variable vapour diffusion membrane between plates - Galvanized steel structural profile - 15 cm Rigid rock wool panel insulation - 7+7 cm - Osb board 3 - 1.20 cm - Exterior thermal cladding with one-brand Etics insulation system, consisting of: - Bonding mortar - Thermal insulation in rigid expanded polystyrene (Eps) boards - 6 cm - Complementary mechanical clamping bushings - Coating mortar (1st layer) - Anti-alkaline fibreglass net - Coating mortar (2nd layer) - Primary coating as bottom regulator - Light-coloured decorative final finish coating mortar. EXTERIOR Walls (concrete) - Current Solution Single wall with thermal insulation from the outside, consisting from the inside to the outside of: - Paint (dry zone) or cement glue + ceramic coating (wet area) - Normal plasterboard (dry zone) or water-repellent (wet zone) plasterboard - 2x 1.25 cm - Variable vapour diffusion membrane between plates - Galvanized steel structural profile - 9 cm Rigid rock wool panel insulation - 4+4 cm - Air space - Reinforced concrete wall - 25 cm - Exterior thermal cladding with one-brand Etics insulation system. EXTERIOR Roofs - Current Solution Roof with thermal insulation from the outside, consisting of the following from the outside to the inside: - Waterproofing in bonded bituminous membrane (Sbs or App) with polyester felt reinforcement and finished with sun protection layer in white mineral granule for greater reflection and reduced heat absorption - Adhered bituminous membrane (Sbs or App) with fibreglass reinforcement and plastic film finish - Thermal insulation in rigid high-density rock wool panels finished in oxyasphalt irrigation on the upper face, mechanically fixed to the support - 5 cm - Waterproof umbrella membrane - Osb 3 boards - 1.80 cm - Galvanized steel structural profile for slope formation non-ventilated air space - Osb boards 3 - 1.8 cm - Galvanized steel structural profile - 20 cm Rigid rock wool panel insulation - 7 cm | unventilated air space - Galvanized steel roof support structure non-ventilated air space - Rigid rock wool panel insulation - 7 cm - Variable vapour diffusion membrane - Suspended false ceiling in normal plasterboard (dry zone) or water-repellent (wet zone) - 1.25 cm -Ink. Energy Rating: A ref:TER 704
ส่งอีเมลสอบถามได้ที่ SF Properties
รหัสอสังหาริมทรัพย์: 120090373759